INSTALLING THE HIGH/LOW SENSITIVITY RING


(SEE FIGURE 3)

NOTE - WHEN TESTING EXTREMELY SMALL MAGNETIC FIELDS SUCH AS SUB-MINIATURE SOLENOIDS AND RELAYS, THE HIGH SENSITIVITY RING MUST BE USED. 1.) HOLD THE HIGH SENSITIVITY RING BETWEEN THE INDEX FINGER AND THUMB WITH THE WHITE DOT ON THE RING TOWARD THE PALM OF YOUR LEFT HAND.

 2.) SLIDE THE RING ONTO THE TIP TOWARD THE BODY OF THE MAG-PROBE UNTIL THE RED LED GOES OUT THE FIRST TIME. (SEE FIGURE NO. 4)

 3.) CONTINUE SLIDING THE RING TOWARD THE MAG-PROBE BODY UNTIL THE LED TURNS ON AND THEN OFF FOR THE SECOND TIME. (SEE FIGURE 5) NOW THE MAG-PROBE IS ADJUSTED FOR HIGH SENSITIVITY. TO BE SURE YOU HAVE THE HIGHEST SENSITIVITY OBTAINABLE. SLIDE THE RING BACK UNTIL THE LIGHT IMMEDIATELY TURNS ON. THEN WITH THE TIP OF THE INDEX FINGER AND THUMB PRESSED AGAINST THE RING (FIGURE 3). USE A SLIGHT PINCHING MOTION TO MOVE THE RING TOWARD THE BODY OF THE MAG-PROBE. RELEASE IMMEDIATELY AS SOON AS THE LED TURNS OFF. REMEMBER, FIGURE 5 IS THE CORRECT POSITION.
 

NOTE: ANY MOVEMENT OF THE RING AFTER THE LED GOES OUT WILL DECREASE SENSITIVITY.

CAUTION:
TO AVOID FALSE INDICATIONS WHEN USING THE HIGH SENSITIVITY RING, THE RING MUST NOT TOUGH A METAL SURFACE, BUT YOU MAY TOUCH A METAL SURFACE WITH THE MAG-PROBE�S TIP.

REMEMBER:

FIRST TRY YOUR MAG-PROBE WITHOUT THE HIGH SENSITIVITY RING. THEN IF YOU NEED THE HIGH SENSITIVITY TO DETECT THE DEVICE UNDER TEST, SLIP ON THE RING.

YOU�LL SEE ONLY A SMALL DIFFERENCE IN SENSITIVITY BETWEEN THE MODEL �S� AND MODEL �HS� IF YOU DON�T USE THE HIGH/LOW SENSITIVITY RING.
THE MODEL �HS� MUST MEET A MINIMUM SENSITIVITY TEST. APPROXIMATELY TWICE THAT OF THE MODEL �S� WITH THE HIGH/LOW SENSITIVITY RING ATTACHED.
 

 TESTING AC POWERED DEVICES WITH THE HIGH/LOW SENSITIVITY RING INSTALLED
 

YOU WON�T HAVE ANY PROBLEMS TESTING ANY AC POWERED DEVICE REGARDLESS OF WHICH END OR SIDE YOU TEST JUST AS LONG AS THE FIELD STRENGTH IS WITHIN THE �MAG-PROBE�S� SENSITIVITY RANGE.
 

 TESTING DC POWERED DEVICES WITH THE HIGH/LOW SENSITIVITY RING INSTALLED


 WHEN USING THE HIGH/LOW SENSITIVITY RING, THE �MAG-PROBE� BECOMES SENSITIVE TO NORTH AND SOUTH POLES. WHITE DOT TOWARD THE �MAG-PROBE�S� TIP, NORTH AND WHEN THE RING IS REMOVED AND INSTALLED WITH THE WHITE DOT ON THE RING TOWARDS THE �MAG-PROBE�S� LED, YOU�LL DETECT ONLY BY SOUTH POLES.

DC POWERED DEVICES CAN BE CONNECTED TO A POWER SOURCE 2 WAYS. (SEE FIGURE 6A & 6B)

IN FIGURE 6A, ASSUME THAT A NORTH POLE OCCURS AT THE COIL�S UPPER END WHEN A DC VOLTAGE IS APPLIED AS SHOWN. IF THE POLARITY OF THE APPLIED VOLTAGE IS REVERSED AS SHOWN IN FIGURE 6B, A SOUTH POLE IS GENERATED AT THE UPPER END. TRY BOTH ENDS OF AN OPERATING SOLENOID, RELAY, REED RELAY, OR DC DEVICE. ONCE YOU ESTABLISH WHIHC END OF THE RELAY OR DC DEVICE CAUSES THE �MAG-PROBE� TO OPERATE, THE OTHER RELAYS OR DC DEVICES INSTALLED IN THE INSTRUMENT UNDER TEST SHOULD RESPOND AT THE SAME END.
SEE FIGURE 7

PHOTO SHOWING TESTS ON BOTH ENDS OF A DC SOLENOID

 

SINCE REED RELAYS ARE DC POWERED, YOU MUST FOLLOW THE ABOVE INSTRUCTIONS FOR TESTING DC POWERED DEVICES.

IF A REED RELAYS ARE DC POWERED, YOU MUST FOLLOW THE ABOVE INSTRUCTIONS FOR TESTING DC POWERED DEVICES.

IF A REED RELAY IS MOUNTED IN SUCH A WAY THAT YOU ARE UNABLE TO REACH THE NORMALLY TESTED END, REVERSE THE HIGH/LOW SENSITIVITY RING AND TEST THE ACCESSIBLE END (OPPOSITE). SEE FIGURE 8